Right Angle PN 15452-90 Standard 3/4" Black Plastic Meter Dome used on some residential Fleck 2500, 2510 and 8500 Metered Valves.
The "meter cover", can be the reason your
Fleck 2500 or 2510 Econominder is not regenerating automatically. Once you have
determined the timer motor is functioning properly, the meter is the
next part to check.
1) Is the cable securely connected at the valve head side?
This connection is inside the back of the timer control head.
2) With the valve in By Pass or the water off, remove the
meter cover. Four screws hold it in place. Note how it is installed so
you can replace it the same way it came out.
You need to check for debris or build up around the impeller,
part # 13509 ( looks like a paddle wheel ) in the meter body.
3)With the cable disconnected from the meter cover,
does the cable move the program wheel ( the dial on the front of your timer
head ) freely by hand?
4) The way to test the meter cover portion, is to remove it.
With the cable connected to the meter cover, turn the cable with your hand.
You should be able to cause the white gears inside the meter cover to
spin ( looking from the underside of the meter cover ) . They should continue to spin for a second after you stop twisting the cable by
hand. If it is very very hard to move, or stops as soon as you stop applying pressure, then you need a new meter cover.